Combination IO Modules

4DIN+4AIN+2AO+4DO Ethernet Remote IO Module

Item No.: M120
M120 Ethernet  Remote I/O Module provides 4 optical-isolated digital inputs, supports Max. 700KMHz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V, 0~10V, 4~20mA, 0~20mA analog signal, 2 channel 0-10V 12bits analog outputs.
Introduction Features Specifications Download Applications
Modbus Remote I/O
There are many industrial automation devices such as PLC which have a MODBUS Communications facility available. PLC can be configured as a MODBUS Master, and IO modules are attached to the RS485 configured as RTU slaves. PLC system use M120 Modbus RTU IO Module to increasing the I/O capability of the industrial control system. The Modbus remote IO M120 also supports Modbus TCP server and client, SNMP V1/V2, and MQTT protocol. Which is suitable for wide range of industrial data acquisition and remote monitoring applications.

The M120 Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

 
4DI
Wet/Dry contact
High speed pulse
counting
4DO
SINK
High speed pulse
output
4AI
0-20mA/4-20mA
0-5V
0-10V
2AO
0-10V


 
                                               


Item Parameter Description
Power Input voltage
  1. Models without AO: 9~36VDC
  2. Models with AO: 24~36VDC
Power consumption Typical standby power consumption: ≤ 2W
Power Output
  1. 1 channel
  2. Output voltage: 936V DC
  3. Output current: 1500mA@12V(MAX)
Protection Reverse wiring prevention;
ESD Air: 15KV; Surge: 4KV
Ethernet Specification 1 x RJ45, 10M/100Mbps
Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
Protocol Modbus RTU, Modbus TCP, MQTT
Serial port QTY 1 x RS485
Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
Data Bit 7, 8
Parity Bit None, Even, Odd
Stop Bit 0.5, 1, 1.5, 2
Protocol Modbus RTU(slave), Modbus RTU(master)
Protection ESD contact: 8KV  Surge: 4KV(8/20us)
Digital input QTY 16 channel(Max)
Type Support Wet contact(NPN, PNP) and Dry contact.
Default: Wet contact
Dry contact
  1. Close: Short circuit
  2. Open: Open circuits
Wet contact
  1. Close: 10~30VDC
  2. Open: 0~3VDC
Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
Isolated protection 2KVrms
Sampling Rate 100Hz
Digital output QTY 16 channels(Max)
Type SINK
Capacity 500mA per contact
Overvoltage protection 50VDC
Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
Analog input (12bit) QTY 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution 12Bit
Accuracy
  1. ±0.1% FSR @ 25°C
  2. ±0.3% FSR @ -10 and 60°C
  3. ±0.5% FSR @ -40 and 75°C
Sampling Rate 20Hz
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Analog input (16bit) QTY
  1. 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution
  1. 16Bit
Accuracy
  1. ±0.5‰FSR @ 25°C
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Analog output QTY 2 channels
Method Single-ended to ground
Type 0~10VDC
Resolution 12Bit
Accuracy
  1. ±0.1% FSR @ 25°C
  2. ±0.3% FSR @ -10 and 60°C
  3. ±0.5% FSR @ -40 and 75°C
Maximum load 1000mA
Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
Protocol conversion Support Modbus TCP and RTU protocol conversion
Support Modbus RTU to MQTT and Modbus TCP to MQTT
Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
Map data bool: 300
16bit: 300
Login Package Support custom login package
Heartbeat Package Support custom heartbeat package
Environment Working -2070°C, 595%RH
Storage -4085°C, 595%RH
Others Case Metal
Dimension 82mm×40mm×100mm
Protection grade IP30
Net Weight 450g
Installation DIN rail mounted, Wall-mounted
Description
Modbus Remote I/O
There are many industrial automation devices such as PLC which have a MODBUS Communications facility available. PLC can be configured as a MODBUS Master, and IO modules are attached to the RS485 configured as RTU slaves. PLC system use M120 Modbus RTU IO Module to increasing the I/O capability of the industrial control system. The Modbus remote IO M120 also supports Modbus TCP server and client, SNMP V1/V2, and MQTT protocol. Which is suitable for wide range of industrial data acquisition and remote monitoring applications.

The M120 Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

 
4DI
Wet/Dry contact
High speed pulse
counting
4DO
SINK
High speed pulse
output
4AI
0-20mA/4-20mA
0-5V
0-10V
2AO
0-10V


 
                                               


introduction
Features
Specifications
Item Parameter Description
Power Input voltage
  1. Models without AO: 9~36VDC
  2. Models with AO: 24~36VDC
Power consumption Typical standby power consumption: ≤ 2W
Power Output
  1. 1 channel
  2. Output voltage: 936V DC
  3. Output current: 1500mA@12V(MAX)
Protection Reverse wiring prevention;
ESD Air: 15KV; Surge: 4KV
Ethernet Specification 1 x RJ45, 10M/100Mbps
Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
Protocol Modbus RTU, Modbus TCP, MQTT
Serial port QTY 1 x RS485
Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
Data Bit 7, 8
Parity Bit None, Even, Odd
Stop Bit 0.5, 1, 1.5, 2
Protocol Modbus RTU(slave), Modbus RTU(master)
Protection ESD contact: 8KV  Surge: 4KV(8/20us)
Digital input QTY 16 channel(Max)
Type Support Wet contact(NPN, PNP) and Dry contact.
Default: Wet contact
Dry contact
  1. Close: Short circuit
  2. Open: Open circuits
Wet contact
  1. Close: 10~30VDC
  2. Open: 0~3VDC
Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
Isolated protection 2KVrms
Sampling Rate 100Hz
Digital output QTY 16 channels(Max)
Type SINK
Capacity 500mA per contact
Overvoltage protection 50VDC
Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
Analog input (12bit) QTY 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution 12Bit
Accuracy
  1. ±0.1% FSR @ 25°C
  2. ±0.3% FSR @ -10 and 60°C
  3. ±0.5% FSR @ -40 and 75°C
Sampling Rate 20Hz
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Analog input (16bit) QTY
  1. 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution
  1. 16Bit
Accuracy
  1. ±0.5‰FSR @ 25°C
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Analog output QTY 2 channels
Method Single-ended to ground
Type 0~10VDC
Resolution 12Bit
Accuracy
  1. ±0.1% FSR @ 25°C
  2. ±0.3% FSR @ -10 and 60°C
  3. ±0.5% FSR @ -40 and 75°C
Maximum load 1000mA
Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
Protocol conversion Support Modbus TCP and RTU protocol conversion
Support Modbus RTU to MQTT and Modbus TCP to MQTT
Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
Map data bool: 300
16bit: 300
Login Package Support custom login package
Heartbeat Package Support custom heartbeat package
Environment Working -2070°C, 595%RH
Storage -4085°C, 595%RH
Others Case Metal
Dimension 82mm×40mm×100mm
Protection grade IP30
Net Weight 450g
Installation DIN rail mounted, Wall-mounted
Download
Applications

Review